VECTRON G 2 - 6
Power 40 to 1,907 kW
ELCO does not supply off-the-shelf heating technology. As a partner to the specialist installers, we do everything we can to ensure that you can offer each of your customers a customised heating solution. A comprehensive solution that best fulfils their expectations in terms of comfort, safety and energy savings. In a quality that lasts for decades. With a service that sets standards in the industry. That's what we consider market-orientated. This also and especially applies to the new VECTRON generation.
Informative
Display with clearly understandable visual language
Safe
High operational reliability and first-class combustion values
Simple
Quick installation and easy handling
Precise
Digital automatic burner control for high-precision setting, optimised commissioning and maintenance functions.
Reliable
Without complicated or fault-prone components
Technical Data VECTRON L 2 - 6 | Performance [kW] | Default setting power [kW] | Operating mode | ø Burner tube x immersion depth [mm] | Examination |
BLUE 2.38 VD | 22 - 38 | 35 | two-stage, with speed-controlled fan | 80 / 100 x 235 - 265 | EN 267 |
BLUE 2.45 VD | 25 - 44 | 40 | two-stage, with speed-controlled fan | 80 / 100 x 235 - 265 | EN 267 |
BLUE 2.54 VD | 32 - 57 | 50 | two-stage, with speed-controlled fan | 80 / 120 x 235 - 265 | EN 267 |
BLUE 2.66 VD | 40 - 66 | 63 | two-stage, with speed-controlled fan | 100 / 120 x 230 - 320 | EN 267 |
BLUE 2.77 VD | 45 - 77 | 71 | two-stage, with speed-controlled fan | 100 / 120 x 230 - 320 | EN 267 |
BLUE 2.85 VD | 48 - 85 | 79 | two-stage, with speed-controlled fan | 100 / 120 x 230 - 320 | EN 267 |
BLUE 2.95 VD | 52 - 95 | 83 | two-stage, with speed-controlled fan | 100 / 120 x 230 - 320 | EN 267 |
BLUE 2.100 VD | 55 - 100 | 88 | two-stage, with speed-controlled fan | 100 / 120 x 230 - 320 | EN 267 |
L 2.140 | 80 - 140 | 100 | one-stage | 100 x 30 - 270 | EN 267 |
L 2.200 | 130 - 200 | 160 | one-stage | 100 x 30 - 270 | EN 267 |
L 2.120 DUO | 60 - 120 | 100 | two-stage | 115 x 30 - 270 | EN 267 |
L 2.160 DUO | 80 - 160 | 140 | two-stage | 115 x 30 - 270 | EN 267 |
L 2.210 DUO | 100 - 205 | 170 | two-stage | 115 x 30 - 270 | EN 267 |
L 3.290 DUO | 130 - 290 | - | two-stage | 130 x 180 or 320 | EN 267 / emission class 2 |
L 3.360 DUO | 170 - 360 | - | two-stage | 130 x 180 or 320 | EN 267 / emission class 2 |
ECO L 04.270 DUO | 80 - 265 | - | two-stage | 130 x 150 | EN 267 |
L 4.460 DUO | 180 - 460 | - | two-stage | 150 x 220 or 360 | EN 267 |
L 4.610 DUO | 195 - 610 | - | two-stage | 150 x 220 or 360 | EN 267 |
ECO L 05.400 DUO | 160 - 400 | - | two-stage | 170 x 325 | EN 267 |
ECO L 05.600 DUO | 280 - 600 | - | two-stage | 170 x 325 | EN 267 |
L 5.950 DUO | 260 - 950 | - | two-stage | 170 x 215 or 325 or 435 | EN 267 |
L 5.1200 DUO | 400 - 1,186 | - | two-stage | 170 x 215 or 325 or 435 | EN 267 |
L 6.1600 DUO PLUS | 320 - 1,600 | - | three-stage | 227 x 270 or 370 or 470 | EN 267 |
L 6.2100 DUO PLUS | 400 - 2,080 | - | three-stage | 227 x 270 or 370 or 470 | EN 267 |
Heating oil meter
An oil meter can be installed under the burner bonnet to monitor oil consumption.
Heating oil filter
The supply of clean, air-free oil is a requirement for trouble-free burner operation. A venting filter is available for direct installation in front of the burner for this purpose.
Water protection valve
In the event of a leak in the oil line, the oil tank must be prevented from being lifted by a water protection valve. The kit enables simple electrical connection of the valve to the burner.
Air intake connection
For an external air supply, an air intake device is available for connecting the burner to the air duct.
Remote release
If the burner is located under a sound insulation or boiler bonnet, it can be connected to a switch located in the boiler control panel via a remote release cable.