VECTRON G 2 - 6
Power 40 to 1,907 kW
ELCO does not supply off-the-shelf heating technology. As a partner to the specialist installers, we do everything we can to ensure that you can offer each of your customers a customised heating solution. A comprehensive solution that best fulfils their expectations in terms of comfort, safety and energy savings. In a quality that lasts for decades. With a service that sets standards in the industry. That's what we consider market-orientated. This also and especially applies to the new VECTRON generation.
Intelligent
Manual fuel switching directly on site
Simple
Quick installation and easy handling
Reliable
Without complicated or fault-prone components
Environmentally friendly
Excellent energy utilisation and clean combustion
Flexibe
Wide range of special functions can be set
VECTRON | GL 03.350 DUO | GL 05.700 DUO PLUS | GL 05.1000 DUO PLUS | GL 06.1600 DUO PLUS | GL 06.2100 DUO PLUS |
---|---|---|---|---|---|
Performance min. [kW] | 118 | 200 | 240 | 300 | 480 |
Performance max. [kW] | 350 | 700 | 1000 | 1600 | 2050 |
Compact gas fitting | CG 340 - VT 2 | MBVEF 412 / 420 | MBVEF 412 / 420 or VGG 10 or VGF 10 | MBVEF 412 / 420 or VGD 20 / 40 | MBVEF 420 or VGD 20 / 40 |
Operating mode | Gas: modulating / Oil: two-stage | Gas: two-stage gliding / modulating /Oil: two-stage | Gas: two-stage gliding / modulating /Oil: two-stage | Gas: two-stage gliding / modulating / Oil: three-stage | Gas: two-stage gliding / modulating / Oil: three-stage |
ø Burner tube x immersion depth [mm] | 149 x 115 - 300 | 170 x 215 and 325 and 435 | 170 x 215 and 325 and 435 | 227 x 270 and 370 | 227 x 270 and 370 and 470 |
Examination | EN 267 & EN 676 | EN 267 & EN 676 | EN 267 & EN 676 | EN 267 | EN 267 |
CE label | 0065 AQ 1117 | 1312 AR 2061 | 1312 AR 2062 | 1312 BM 3427 | 1312 BM 3428 |
Gas connection accessories
The burner is flexibly connected to the gas pipe via a gas hose, which can be quickly and safely disconnected using a quick-release coupling and an upstream ball valve. A gas meter is used to monitor gas consumption.
Connection set for external gas valve
The safety valve, which is normally located outside the boiler room, is simply controlled via the burner using a connection kit.
Power regulator
A modern electronic controller can be installed directly under the burner bonnet to regulate the output of the burner.
Air intake connection
For the external air supply, an air intake connection is available for connecting the burner to the air duct.
Remote release
If the burner is located under a sound insulation or boiler bonnet, it can be connected to a switch located in the boiler control panel via a remote release cable.