VECTRON G 2 - 6
VECTRON G 2 - 6

VECTRON G 2 - 6

Power 40 to 1,907 kW
Gas is one of the most important energy sources today and in the future. ELCO offers you a burner programme that does justice to the importance of this energy source. What all VECTRON gas burners have in common is the optimised burner head design, which makes heating with gas even more efficient and environmentally friendly.
 
 

A customised heating solution for every requirement

ELCO does not supply off-the-shelf heating technology. As a partner to the specialist installers, we do everything we can to ensure that you can offer each of your customers a customised heating solution. A comprehensive solution that best fulfils their expectations in terms of comfort, safety and energy savings. In a quality that lasts for decades. With a service that sets standards in the industry. That's what we consider market-orientated. This also and especially applies to the new VECTRON generation.

Key features at a glance

Informative

Informative

Display with clearly understandable visual language

Reliable

Reliable

Without complicated or fault-prone components

Simple

Simple

Quick installation and easy handling

Environmentally friendly

Environmentally friendly

Excellent energy utilisation and clean combustion

Flexible

Flexible

Wide range of special functions can be set

 

Technical Information

Technical Data VECTRON G 2 - 6 Performance [kW] Compact gas fitting Operating mode ø Burner tube x immersion depth [mm] CE label
G 2.160 DUO 60 - 160 MBZRDLE 407 two-stage 115 x 30 - 270 1312 BQ 4069
G 2.210 DUO 80 - 210 MBZRDLE 412 two-stage 115 x 30 - 270 1312 BQ 4069
G 2.210 VARIO 80-210 MBVEF 412 modulating with speed control 115 x 30 - 270 1312 BQ 4069
G 2.120 MODULO / TC 30 - 120 MBC 300 SE modulating with electronic compound 115 x 30 - 270 1312 BQ 4069
G 2.160 MODULO / TC 40 - 160 MBC 300 SE modulating with electronic compound 115 x 30 - 270 1312 BQ 4069
G 2.210 MODULO / TC 40 - 210 MBC 300 SE modulating with electronic compound 115 x 30 - 270 1312 BQ 4069
G 3.290 DUO 95 - 290 MBZRDLE 407 / 412 two-stage 130 x 180 and 320 1312 BV 5208
G 3.360 DUO 120 - 360 MBZRDLE 407 / 412 / 420 two-stage 130 x 180 and 320 1312 BV 5208
G 3.290 DUO PLUS 70 - 290 MBVEF 407 / 412 two-stage gliding / modulating 130 x 180 and 320 1312 BV 5208
G 3.360 DUO PLUS 80 - 360 MBVEF 407 / 412 / 420 two-stage gliding / modulating 130 x 180 and 320 1312 BV 5208
G 3.290 VARIO 70 - 290 MBVEF 407 / 412 modulating with speed control 130 x 180 and 320 1312 BV 5208
G 3.360 VARIO 80 - 360 MBVEF 407 / 412 / 420 modulating with speed control 130 x 180 and 320 1312 BV 5208
G 3.290 MODULO / TC 50 - 290 MBC 300 SE modulating with electronic compound 130 x 180 and 320 1312 BV 5208
G 3.360 MODULO / TC 60 - 360 MBC 300 SE / MBC 700 SE modulating with electronic compound 130 x 180 and 320 1312 BV 5208
G 4.460 DUO 150 - 460 MBZRDLE 407 / 412 / 420 two-stage 150 x 220 and 360 1312 CL 5412
G 4.460 DUO PLUS 100 - 460 MBVEF 407 / 412 / 420 two-stage gliding / modulating 150 x 220 and 360 1312 CL 5412
G 4.610 DUO PLUS 130 - 610 MBVEF 407 / 412 / 420 two-stage gliding / modulating 150 x 220 and 360 1312 CL 5412
G 4.460 MODULO / TC 86 - 460 MBC 300 / 700 SE modulating with electronic compound 150 x 220 and 360 0085 CN 0192
G 4.610 MODULO / TC 90 - 610 MBC 300 / 700 SE modulating with electronic compound 150 x 220 and 360 0085 CN 0192
G 04.570 VARIO 140 - 570 MBVEF 412 / 420 modulating with speed control 150 x 200 and 350 1312 BN 3682
G 5.950 DUO PLUS 170 - 950 MBVEF 412 / 420 or VGD 20 two-stage gliding / modulating 170 x 215 and 325 and 435 1312 CM 5579
G 5.1200 DUO PLUS 250 - 1160 MBVEF 412 / 420 or VGD 20 / 40 two-stage gliding / modulating 170 x 215 and 325 and 435 1312 CM 5579
G 5.950 MODULO / TC 160 - 950 MBC 300 / 700 / 1200 SE or VGD 40 modulating with electronic compound 170 x 215 and 325 and 435 0085 CN 0192
G 5.1200 MODULO / TC 160 - 1160 MBC 300 / 700 / 1200 SE or VGD 40 modulating with electronic compound 170 x 215 and 325 and 435 0085 CN 0192
G 6.1600 DUO PLUS / TC 300 - 1600 MBVEF 412 / 420 or VGD 20 / 40 (DN65) modulating with pneumatic compound 227 x 360 and 460 and 560 1312 CN 5685
G 6.2100 DUO PLUS / TC 400 - 1907 MBVEF 412 / 420 or VGD 20 / 40 (DN65 or DN80) modulating with pneumatic compound 227 x 360 and 460 and 560 1312 CN 5685
G 6.1600 MODULO / TC 300 - 1600 MBC 700 / 1200 SE or VGD 40 modulating with electronic compound 227 x 360 and 460 and 560 0085 CN 0192
G 6.1600 MODULO / TC 400 - 1907 MBC 700 / 1200 SE or VGD 40 modulating with electronic compound 227 x 360 and 460 and 560 0085 CN 0192

Solutions

 
First Class Service

First Class Service

People say we offer the best customer service in the industry: in fact, we are there for our customers 365 days a year, 24 hours a day. With more than 800 service engineers in Europe.

MORE ABOUT SERVICE AT ELCO
 
Your heating always at hand - with REMOCON NET

Your heating always at hand - with REMOCON NET

Wouldn't it be nice if you could set the ideal room temperature at the touch of a button before you get home? With the ELCO REMOCON-NET app for your smartphone, you can control your heating system anytime, anywhere. Adjust the settings for optimum energy consumption and save money.

MORE ABOUT REMOCON NET
 
Our references - your security

Our references - your security

Our customers love their heating solutions from ELCO. That's why they are happy to give us an insight into their heating centres. That makes us happy and, of course, very proud!

TO OUR REFERENCES
 

Accessories

Gas connection accessories

Gas connection accessories

The burner is flexibly connected to the gas pipe via a gas hose, which can be quickly and safely disconnected using a quick-release coupling and an upstream ball valve. A gas meter is used to monitor gas consumption.

Connection set for external gas valve

Connection set for external gas valve

The safety valve, which is normally located outside the boiler room, is simply controlled via the burner using a connection kit.

Power regulator

Power regulator

A modern electronic controller can be installed directly under the burner bonnet to regulate the output of the burner.

Air intake connection

Air intake connection

For the external air supply, an air intake connection is available for connecting the burner to the air duct.

Remote release

Remote release

If the burner is located under a sound insulation or boiler bonnet, it can be connected to a switch located in the boiler control panel via a remote release cable.